MOM and SCDF Just Shortened the Life of Every Timber Scaffold

Construction site at dusk with netted scaffolding and a safety inspector reviewing fire safety compliance

FIRE SAFETY

MOM and SCDF just put a hard expiry date on every timber scaffold in Singapore and a fire-test requirement on every metre of netting wrapped around a building site. The circular lands quietly in September; the deadlines start biting in January 2027 — and the compliance paperwork it demands is only half the job a site actually needs to do.

A Joint Circular, Not Just Another Memo

On 25 September 2026, MOM’s Occupational Safety and Health Division and the Singapore Civil Defence Force issued a joint circular — MOM/OSHD/2026-03 — introducing new scaffold fire safety requirements under the Workplace Safety and Health (Scaffolds) Regulations 2011 and the Fifth Schedule to the WSH Act. Joint sign-off between MOM and SCDF on a scaffolds circular is itself a signal: this isn’t a procedural tidy-up, it’s a response to a recognised fire-spread risk sitting in plain sight on thousands of active worksites — combustible timber and netting wrapped around a building, often for months at a stretch.

The Timber Clock Just Got Much Shorter

From 1 January 2027, the permissible duration for timber scaffolds drops from nine months to three. Timber erected before that date can still run its full nine-month course, but anything new goes up against the three-month ceiling from day one. MOM’s own reasoning is blunt: timber is combustible, it accelerates fire spread once ignited, and the longer it sits on a site — especially one where hot works are underway — the longer that exposure lasts. Extensions exist, but MOM has been explicit that cost savings, convenience or poor planning won’t qualify; a company needs genuine technical constraints, a documented risk assessment and a clear fire safety and inspection plan before the Commissioner will even consider a case-by-case approval.

Netting Gets a Fire Test, a Batch Number and a Paper Trail

The second change is the one that touches more suppliers than contractors. From 1 March 2027, any netting used to envelope a scaffold erected outside a building — the overlay or screening nets that catch falling debris — must be fire-retardant, tested to one of three accepted standards (NFPA 701:2023, BS 5867-2:2008 Type B, or JIS L 1091:1999 under specified categories). Manufacturers and suppliers must hand over a fire test report at the point of sale and label every net with a batch number traceable back to it; occupiers and scaffold contractors don’t run the test themselves, but they do have to keep that report on hand for MOM to inspect on the spot. Scaffold netting is also being added to the Fifth Schedule of the WSH Act, which formally places upstream testing duties on whoever manufactures or supplies it. A third-party certification scheme through Singapore Accreditation Council-accredited bodies follows on 1 March 2028, closing the loop with independent verification rather than self-declared compliance.

The Part the Circular Doesn’t Spell Out

Here’s what the circular is careful about and what it leaves to the site: Annex A’s fire safety management measures — keeping combustible materials away from scaffolding and netting, maintaining fire-watch vigilance, ensuring escape routes stay clear, keeping hose reels and hydrants unobstructed — are all instructions about what a site must do, not what it must visibly tell workers and visitors it’s doing. A fire test report in a site office folder proves the netting is compliant to an inspector. It does nothing for the subcontractor walking past a hot-works zone who doesn’t know a naked-flame restriction applies three metres from where fresh netting was just installed. That gap between a documented control and a posted one is exactly the pattern MOM’s own enforcement data has flagged all year, across haze readiness, confined-space entry and heat stress alike.

What a Scaffold-Heavy Site Should Be Posting Before January

For any contractor or occupier running timber scaffolds or netted elevations now, the practical signage checklist sits right alongside the compliance paperwork: no-naked-flame and no-smoking signage at every point where netting or timber scaffold meets a hot-works permit area; a visible fire extinguisher and hose reel location sign at each scaffold access point, matched to what Annex A asks site teams to check is in working order; a clearly posted scaffold erection date and removal-by date at the structure itself, backing up the scaffold register MOM expects supervisors to keep; and standard fire action and emergency escape signage kept unobstructed exactly where scaffold works tend to encroach on a building’s existing escape routes. None of this replaces the fire test report or the batch label the regulation demands — it’s what makes the control real for the person standing next to the scaffold rather than the one reading the file afterward.

Nine months to three, and self-declared to third-party certified by 2028 — MOM and SCDF have given the industry a clear runway, but the runway is short and the paperwork alone won’t stop a fire from spreading once combustible netting is up. Browse our full range of SS 508-compliant fire safety signs at safetysigns.sg.

Author: safetysigns.sg Team
Date: 17 November 2026